We ship nationwide. 30-day return policy. CALL US NOW 0800 477 746
Couldn't load pickup availability
Please call us at 0800477746 to discuss and apply on our very affordable rental option.
Version: 1.1
Date Created: March 2025
New regulations have been made to provide building product users with a minimum level of easy to understand information about building products
These new regulations were developed to
Help designers, builders and consumers choose the right products for their needs ,install them correctly and make informed decisions about using alternative products if required
Enable more efficient consenting by providing building consent authorities with the right information, so it is readily available to check that plans will meet the building code
Reduced the chance of building defects, less building rework, more efficient consenting, and safer more durable buildings
These BPIR relate to our Underbench Unit Tapware Range including:
Spring Neotap Multi – Light Commercial (LC)
Spring Neotap Soft Touch – Residential (R)
Spring Fusion Tap
Spring Duo Tap
Spring Filter Tap
in all incarnations/colourways. This BPIR is only required for the tapware, not the respective underbench appliance
This Tapware is designed for use with the applicable underbench appliance for filtered, tempered drinking water
These products are batch produced to a general specification, and are Class 1 Building Products as defined in the regulations
RELEVANT BUILDING CODE CLAUSES
CONTRIBUTION TO COMPLIANCE
G12.1B The objective of this position is to safeguard people from injury caused by hot water system explosion, or from contact with excessively hot water
Safety – Water Supply system has a double lock system before dispensing hot water
G12.3.3 A non-potable water supply system used for personal hygiene must be installed in a manner that avoids the likelihood of illness or injury being caused by the system
Safety – Water Supply system has a double lock system before dispensing hot water
G12.3.6 If hot water is provided to sanitary fixtures and sanitary appliances used for personal hygiene, it must bedelivered at a temperature that avoids the likelihood of scalding
Safety – Water Supply system has a double lock system before dispensing hot water
G12.3.7 (b) Water supply systems must be installed in a manner that avoids the likelihood of leakage
(c) Allows reasonable access to components likely to need maintenance
(d) Allows the system and any backflow prevention devices to be isolated for testing and maintenance
Significant Leak (Internal Leak) – Product has a leak detection system integrated to prevent against this and turn off water supply to tap
Installation guide states unit not be installed permanently or sealed away to allow access for service and maintenance
Unit has isolation valve fitted
G12.3.8 Vessels used for producing or storing hot water must be provided with safety features
(a) Relieve excess pressure during both normal and abnormal conditions
(b) Limit temperatures to avoid the likelihood of flash steam production in the event of rupture
Unit has an open vented system to avoid pressure on the boiler unit (Underbench Unit)
G12.3.9 A Hot water system must be capable of being controlled to to prevent the growth of Legionella Bacteria
Boiler unit is at a controlled temperature to prevent the growth of Legionella bacteria (Underbench Unit)
Limitations, design, installation and maintenance requirements are outlined in the instruction manual and product data sheet of the product
This can be found via the links below, included in the package and via the product page
Spring Neotap Multi R – Installation Guide
Spring Neotap Multi LC – Installation Guide
Spring Neotap Soft Touch R – Hot, Cold, Sparkling Installation Guide
Spring Neotap Soft Touch R – Cold, Sparkling, Ambient Installation Guide
Spring Neotap Soft Touch R – Hot, Cold, Ambient Installation Guide
Spring Neotap Soft Touch LC – Installation Guide
Spring Fusion Tap – Description
Spring Duo Tap – Description
Spring Filter Tap – Description
These building products are not subject to warning or ban under section 26 of the Building Act 2004
MANUFACTURER INFORMATION
All Spring Tapware packages are assembled under the control of Fresh Water Company Limited T/a Spring Water Solutions
Assembly is done in house using local and overseas supplied components
IMPORTER/MAINTENANCE CONTACT DETAILS
Fresh Water Company Limited T/a Spring Water Solutions
NZBN: 9429035719229
Company Number: 1421919
119d Captain Springs Road, Onehunga, Auckland 1643
www.springnz.co.nz
info@springnz.co.nz

Commercial-grade 5-water-type tap with dual boiler system. Perfect for offices, cafes & busy kitchens. Fits standard mixer hole - no extra drilling required.
From $5,600.00
Upgrade your commercial kitchen or high-demand residential space with the NeoTap Multi Light Commercial (LC) - New Zealand's most advanced 5-in-1 water tap system engineered for professional environments. Featuring dual boiler technology for continuous hot water supply and commercial-grade construction, this premium faucet delivers filtered hot, chilled, and sparkling water plus regular tap functions - all from one sophisticated unit that fits your existing mixer hole.
No bench modification. Maximum functionality. Professional performance.
Enhanced Light Commercial Features:
Precision rotary control with color-coded LED feedback:
|
LED Color
|
Function
|
Application
|
|---|---|---|
|
Blue
|
System locked - safe mode
|
No dispensing, child-safe
|
|
Light Blue
|
Chilled filtered water
|
Perfect for drinking, beverages
|
|
Green
|
Sparkling water
|
On-demand carbonated water
|
|
Red
|
Near-boiling water (98°C)
|
Tea service, cooking prep
|
|
Blinking Red
|
Hot water safety confirmation
|
3-second safety verification
|
|
Purple
|
System heating in progress
|
Visual heating status
|
Traditional mixer operation for commercial cleaning needs:
|
Finish
|
Characteristics
|
Best Commercial Use
|
|---|---|---|
|
Chrome
|
Mirror-bright, easy cleaning
|
Traditional cafes, restaurants
|
|
Brushed Nickel
|
Fingerprint resistant, professional
|
Modern offices, hotels
|
|
Matte Black
|
Bold statement, contemporary
|
Design-focused venues, bars
|
|
Gun Metal
|
Premium dark metallic
|
High-end restaurants, luxury spaces
|
✅ NeoTap Multi LC Faucet - Commercial-grade 5-in-1 system
✅ Dual Under-Bench Units - Enhanced capacity with additional boiler
✅ Commercial Installation Kit - Professional-grade fittings and connections
✅ Premium Filtration System - Commercial water quality standards
✅ 2.2L CO2 Cartridge - Immediate sparkling water capability
✅ Commercial Warranty - Enhanced coverage for business use
✅ Installation Documentation - Professional setup and compliance certificates
|
Feature
|
Specification
|
Commercial Benefit
|
|---|---|---|
|
Hot Water Capacity
|
Dual boiler - continuous supply
|
No service interruptions
|
|
Hot Water Temperature
|
98°C ± 1°C
|
Perfect for food service
|
|
Chilled Water Temp
|
4-8°C
|
Optimal for beverage service
|
|
Flow Rate (Filtered)
|
2.5L/min
|
Professional service speed
|
|
Flow Rate (Domestic)
|
12L/min
|
Commercial cleaning capability
|
|
Recovery Time
|
Zero with dual boiler
|
Continuous operation
|
Get customized pricing and installation timeline:
Phone: 0800 477 746
Email: info@springnz.co.nz
Online Quote: Professional assessment in 24 hours
Transform your commercial kitchen or office with New Zealand's most advanced professional water system. Experience the productivity, convenience, and professional image benefits of NeoTap Multi Light Commercial.
SPRING-NEOTAP-MULTI-LC-specsheet-v2.pdf
Don't let inadequate water systems limit your business potential. The NeoTap Multi Light Commercial provides the professional-grade functionality, reliability, and image your business deserves.
Contact our commercial specialists today for your customized quote and discover how the right water system can enhance your business operations, staff satisfaction, and customer experience.